Transmetron is a global leader for providing state of the art Menopause
Test Kits. All our tests are FDA Approved and are, in fact, the same tests used
by hospitals and clinics. Our tests are easy to use, easy to read and extremely
accurate.
|
Menopause Test |
 |
Description
FFS-103
- FSH Menopause Test
|
|
|
The
FSH Menopause Predictor
Test is a rapid test
for the detection of FSH (Follicle Stimulating Hormone) in urine to help predict
menopause. Menopause is the permanent ending of menstruation. It is usually not
diagnosed until one full year after a woman’s last menstrual period. The time
leading up to menopause, and the 12 months after, is known as perimenopause.
Many women experience symptoms during this time. These symptoms can include hot
flashes, irregular menstrual cycles, sleep disorders and vaginal dryness.
Hair loss, anxiety and mood
swings, short-term memory loss and fatigue are some other possible symptoms.
Perimenopause starts when
hormone levels in the female body change. As the body ages, it produces less and
less estrogen. FSH levels then increase as the hormone tries to stimulate the
ovaries to produce a healthy egg. Therefore, testing for FSH can help determine
if a woman’s body is producing too much FSH because of low estrogen levels and
is in the perimenopause stage. If a woman knows she is in this stage, she can
take steps to keep her body healthy and avoid the health risks that can come
with menopause. These health risks include osteoporosis, increased blood
pressure and cholesterol, and increased risk of heart disease.
Questions??? -- Give Us A Call at 801-596-2709
WHEN TO TEST
•
If you still have monthly
periods, take the first test during the first week of your cycle (Days 2-7, with
Day 1 being the first day of menstruation). Repeat with the second test 1 week
later.
•
If you no longer have regular
periods, take the test at any time during the month. Repeat with the second test
1 week later.
HOW TO USE
•
Remove the Test from the foil
pouch.
•
Remove the Cap to expose the
Absorbent Tip.
•
Hold the Test Wand by the Thumb
Grip with the exposed Absorbent Tip downward and place directly into the urine
stream for at least 10 seconds (see image). Do not urinate on the Test and
Reference Windows. (If you prefer, you can urinate into a clean dry container.
Dip only the Absorbent Tip of the Test Wand into the urine for at least 10
seconds.)
•
While holding the Absorbent Tip
downward, immediately replace the cap and lay the Test Wand on a flat surface
with the Test and Reference Windows facing upward while you wait for the test
result. DO NOT move the test while the results are developing.
As the test begins to work, you
may notice a light pink color or horizontal lines flowing through the Test and
Reference Windows. Wait 3 minutes from the time you held the Absorbent Tip in
the urine to read the results. If no result appears, wait one minute longer.
Do not read the
result after 8 minutes have passed.
QUESTIONS AND ANSWERS
1. How does the menopause
predictor test work?
As your body ages and produces
less estrogen, FSH levels increase as the hormone tries to stimulate the ovaries
to produce a healthy egg. This test measures FSH and can tell you whether your
body is producing too much FSH because of low estrogen levels. This can signal
that you are in the perimenopause stage.
2. When can I use the
test?
We recommend performing the
test using first morning urine as it contains the most hormone. This will give
the most accurate result. If you are still menstruating, we recommend testing
during the first week of your cycle (see “WHEN TO TEST”) and then retesting 1
week later.
3. If I see pink shading
or horizontal lines in the result windows, is this normal?
After urine is added, you will
see a pink color gradually move across the Test and Reference windows. You may
also see horizontal streaks. This is completely normal and indicates that the
test is working properly.
4. I am not sure that I
held the test in my urine stream long enough. Will I still get an accurate
result?
In order to get an accurate
result, you should hold the Absorbent Tip of the Test in your urine stream for
at least 10 seconds and wait 3 minutes to read the result. If the line in the
Reference Window fails to develop, you should repeat the test.
5. Can I make
contraceptive decisions based on the results of this test?
No. This test cannot determine
fertility. Continue to use contraception until your test results have been
confirmed by your doctor.
6. How accurate is the
test?
In laboratory clinical studies,
the test was shown to be >99% accurate when compared with another
over-the-counter menopause test. In consumer studies, the test was shown to be
>94% accurate overall.
7. How will I know the
test worked?
You must see a line in the
Reference Window. If after 3-4 minutes you do not see a line in the Reference
Window, then the test did not work properly. (Please refer to INVALID RESULT.)
You should review the instructions and repeat with a new test.
8. Do alcohol or common
medications affect the test?
No, alcohol or common
medications should not affect the test results, but you should consult your
physician if you are taking any hormonal medication. Oral contraceptive use and
pregnancy could also affect the test results.
HOW TO READ THE RESULTS
POSITIVE
Two lines are visible and the
color intensity of the Test Line (T) is the
same as
the Reference Line (R).
OR
Two lines are visible and the
color intensity of the Test Line (T) is
darker
than the Reference Line (R). A
positive result means that your FSH level is higher than normal. Record your
results in the table to the right. See the chart below to interpret your
results.
NEGATIVE
Two lines are visible, but the
Test Line (T) is
lighter
than the Reference Line (R).
OR
There is a Reference Line (R),
but there is NO visible Test Line (T). A negative result means that your FSH
levels are not elevated at this time. Record your results in the table to the
right. See the chart below to interpret your results.
INVALID
If you see
no Reference Line
(R) after 3-4 minutes, the
result is invalid. You should repeat the test. The test is not reusable. The
most likely reasons for an invalid result are that not enough urine sample was
used, or the test was performed the wrong way. Review the “HOW TO USE” section
and repeat with a new test.
STORAGE AND HANDLING:
•
Please read all the information
in this leaflet before performing the test.
•
Do not use after the expiration
date stamped on the foil pouch.
•
Store in a dry place at room
temperature 15°-30°C (59°-86°F). Do not freeze.
•
For in-vitro diagnostic use
only. Not to be taken internally. Keep out of reach of children.
•
Do not open the foil pouch
until you are ready to start the test.
Contact Information
For more information about our quality products or, if you are a clinic
or hospital administrator and need bulk pricing, please call our sales office at
(801) 596-2709 Monday through Friday 8 AM to 5 PM MST.
- Telephone
- 801-596-2709
- FAX
- 801-596-7228
- Postal address
- 1725 South 1700 East, SLC UT 84108
- Electronic mail
- General Information:
Transmetron@Connect2.com